Copy/Paste Data, Clone, Custom Symbols, Hide, Destroy/Remove, UNDO, In/Out of Service
Creation, customization and use of Datablocks and Datablock Reports
Efficient management and use of Equipment Libraries
Reporting Options and Customized Output Forms
Import/Export Capabilities
Practical Tips and Advices
Prerequisites:
Basic computer skills
A working knowledge of:
Load Flow calculations
IEC 60909 or IEC 61363 Fault Analysis
Time Current Curves and Coordination Studies
Course Description:
After
this practical introduction training course, you will be able to use
the SKM Power Tools for Windows (PTW) software efficiently. The first
day the trainer will give a presentation about SKM Power Tools and then
he will demonstrate the software. The next day you will try PTW by
yourself, with the support of the trainer. You can either do exercises
handed out during the course, or implement a part of your own power
system in SKM Power Tools. This course is conducted by SKM's long
time distributor - SVRI Electrical Engineering.
Power*Tools for Windows:
Understanding Your License
PTW Modules
Documentation and Support
PTW Project Database
Projects in PTW:
Creating a project
Copy vs Backup
Project Options
Entering Data with the Component Editor
One Line Diagrams:
Creating One Line Diagrams
Using Colors
Changing Symbols
Data Blocks, Text Blocks
Load Flow Studies:
Sources of Supply Representation
Transformer, Load and other Component Representation
Creation of Time-Current Curves from New and Existing Projects
Customization of TCC Drawing Layouts and Libraries
Using Forms to Print TCC Drawings
Export of TCC Drawing to Third Party Application
Input Data Requirements
TCC Settings Report
Arc Flash Evaluation:
Input Data Requirements
Setup Options
Output Report Overview
Understanding Arc Flash Labels
Target Audience:
Power engineers who never used PTW before
Power engineers who want to refresh or extend their PTW knowledge
Managers who want to know exactly the possibilities of PTW
Power engineers and managers who consider to purchase PTW
Course IEC
Intro to SKM Power*Tools for IEC users (the Netherlands) 2-Day Training
Course Date & Hours
June 11 - 12, 2020 (registration form)
November 26 - 27, 2020
9:00 - 17:00 uur. 9:00 AM to 5:00 PM
Course Fees
€ 970,- per person, excluding VAT
Coffee, tea and lunch are included both days
Does not include hotel or travel costs.
If the maximum number of 8 participants is exceeded, we will put you on
the waiting list. If a seat becomes available, the person at the top of
the waiting list can participate. Candidates on the waiting list will
also have priority for the next training.
Course registration is handled by SKM Distributor - SVRI. Email hans.stutvoet@svri.nl for more information.
Licenses
You should bring your laptop computer with the SKM Power Tools software
installed and running. Use your own license (USB key) in preference,
but on your request we will provide the limited 30-day Demonstration
Version of the software in advance. This version has a software key and
may also be installed on your private laptop.
Course Location
CitizenM Rotterdam hotel
Gelderse Plein 50
Rotterdam, NL-3011WZ
the Netherlands